TV and FM Combiners


FDXB-1 and FDXB-2 - DVB Filters for Digital Broadcasting


The DVB filter type FDXB-1 is designed as a part of constant impedance system. The whole unit consists of two filters and two couplers.

The system is very efficient especially in configurations when there is needed simultaneous application of DVB filter and frequency combiner. The filter has a temperature correction.

The system can operate in humidity range from 0% to 90% at 20°C. Each and single part of the filter is designed to reliable function without forced air-cooling.

The filters are made from quality materials only such as aluminum, copper, brass and steel.

The filter has all necessary construction parts for attachment into supporting frame thus allowing any possible placement in transmitting room: on the wall, on the floor or on the roof.

Eventually, the input filters in classic design can be supplied only. This is technically called “Filter with additional coupling”.

Filter with additional coupling has the power rating 400W DVB for FDXB-1 and 1kW for FDXB-2.


Essential for filtering DVB signals and channel’s coupling DVB-T + analog transmitter or DVB-T + DVB-T.

Multiplexer Gysel - 3-way or 6-way

The combiner is intended for combining three or six RF signals to the common output.

The isolation between inputs is realized by using balance resistors (3 or 6 pcs á 250 W) the integral part of the combiner. The balance resistors absorb dissipation power resulting from unequal input power.

      

Specification
Frequency range 470 – 645 MHz
  635 – 860 MHz
Impedance 50 Ω
Output power (average) v 0,5 kW
Peak power ≤ 5 kW
Inputs return loss ≤ -18 dB
Output return loss ≤ -21 dB
Isolation between two arbitrary inputs ≥ 20 dB
Phase deviation ≤ 3°
Insertion loss ≤ 0.3 dB
Dimensions (mm), Gysel 3 way 250 x 230 x 180
Dimensions (mm), Gysel 6 way 250 x 230 x 250

TV channel combiners- 50 Ω

TypeFreq. band [MHz]Power [kW]ConnectorsDimensions[mm] w x h x d
M3.2 470 – 860 2 x 0,5 N 432 x 246 x 109 2
M3.3 470 – 860 3 x 0,25 N 432 x 246 x 218 2
M3.4 470 – 860 4 x 0,1 N 132 x 246 x 327 2
T2XA-1 176 – 230 10 + 5 ø 50; ø 80 500 x 226 x 370 2
T2XA-2 176 – 230 10 + 5 ø 50; ø 80 500 x 226 x 370 2
T2XB-3A 470 – 790 2 x 20 3 1/8 620 x 930 x 2000 >7
T2XB-3B 470 – 790 2 x 20 3 1/8 620 x 930 x 2000 <7
T2XB-4 470 – 790 2 x 20 3 1/8,5 980 x 980 x 2000 >2
T2XB-5 470 – 860 5 + 20 ø 80/34 720 x 433 x 600 2
T2XB-6 470 – 860 50 + 10 3 1/8 500 x 600 x 650 2
T2XB-7 470 – 860 100 *) ø 120 500 x 600 x 800 2
;TSP-3A 470 – 790 2 x 20 ø 80; ø 120 620 x 930 x 2000 >7
TSP-3B 470 – 790 2 x 20 ø 80; ø 120 670 x 1615 x 2000 <7
N+2 470 – 860 2 + 8 ø 25; ø 38 500 x 226 x 370 2

*) total power
• minimal channel spacing


Vision-sound TV combiners

TypFreq. band [MHz]Power [kW] vision + soundConnectorsDimensions[mm] w x h x d
D3 470 – 860 2 + 0,4 N; 7/16; 7/8" 380 x 209 x 205
D4 470 – 854 1 + 0,1 N; 7/16 330 x 260 x 260
  470 – 630 *) 1 + 0,1 N; 7/16 330 x 260 x 260
D6 170 – 230 2 + 0,2 N; 7/16 850 x 490 x 190
DM 470 – 890 1,5 + 0,15 ø 25/10 830 x 500 x 205
D7 44 – 68 25 + 2,5 ø 25; ø 50 650 x 550 x 2200
D8 170 – 230 10 + 1 ø 41,3; ø 25 290 x 460 x 665
D9 470 – 860 10 + 1 ø 41,3; ø 25 480 x 420 x 375
D10 470 – 860 1 + 0,1 N; 7/16 330 x 130 x 260
D11 170 – 230 5 + 0,5 ø 41,3; ø 25 300 x 460 x 665
D12 61 – 100 5 + 0,5 N; 7/16; 7/8" 245 x 350 x 1265
D13 174 – 230 2 + 0,2 ø 25/10 190 x 488 x 850

*) L, NICAM, AM standard


FM channel combiners - 50Ω

TypePower [kW]Dimensions[mm] w x h x d
SH2x05 2 x 0.5 220 x 210 x 976
SH3x05 3 x 0.5 220 x 420 x 976
SH4x05 4 x 0.5 200 x 420 x 976
SH2x2 2 x 2 420 x 374 x 1185
SH3x2 3 x 2 455 x 870 x 1247
SH4x2 4 x 2 455 x 870 x 1247
SHM5x2 5 x 2 + 586 x 1240 x 1042
SHM6x2 6 x 2 + 586 x 1240 x 1042
SH2x5 2 x 5 1130 x 726 x 848
SH3x5 3 x 5 1130 x 1458 x 848
SH4x5 4 x 5 1130 x 1458 x 848
SHM5x5 5 x 5 + 830 x 1240 x 1042
SHM6x5 6 x 5 + 830 x 1240 x 1042
SH2x10 2 x 10 1038 x 1050 x 900
SH3x10 3 x 10 1038 x 2158 x 900
SH4x10 4 x 10 1038 x 2158 x 900
SHM5x10 5 x 10 + 1090 x 1350 x 1465
SHM6x10 6 x 10 + 1090 x 1350 x 1465
+ ... means the augmentation of dimensions of foregoing type Note: some combiners are in two level design, in order to minimise the dimensions